M406 · RTO-144 Connections
M406 Compressor · out 600 Ω
Rear connector
Inputs and outputs
Audio connections · RTO-144 A / B
| Port | Signal | Dir | Pin + | Pin − | Pad + | Pad − |
|---|---|---|---|---|---|---|
| A1 | Compressor IN | in | 1 | 2 | 1.A.1.P | 2.A.1.N |
| A2 | Compressor OUt | out | 13 | 14 | 13.A.2.P | 14.A.2.N |
| B2 | Meter OUT | out | 15 | 16 | 15.B.2.P | 16.B.2.N |
Power · bench PSU
| Rail | Style | Volts | Max A | Supply | Ground | Link |
|---|---|---|---|---|---|---|
| VCC-AUDIO | OLD | 48 | 0.1 | 22 | 18 | — |
| VCC-LAMP | OLD | 24 | 0.1 | 20 | 19 | — |
Source: Ward-Beck Systems - Module RTO-144 Jumper calculator.xlsx (Database tab). Pin direction is inferred from the signal name. Verify against the module schematic before wiring.
WBS Ward-Beck Systems Ltd.
Title
M406 RTO-144 connections
Drn.
make_rto144.py
Date
Oct 17 2026