IndexWiki homeTimelineSearchStatus

M405F

Type module
Category METER
Try it simulator & front panel · download package (zip)
Earliest dated evidence 1984|17 — manual issue date
Evidence "MANUAL ISSUE #1 JUNE 1984" in PUBLIC/Manuals + tech DOCUMENTS/METERING/M405F---Extended-Range-VU-meter-/M405F - 018.jpg
Confidence high
All years found 1984|17
Variants M405, M405C, M405D, M405M, M405P, M405PSS
Folder Modules/METER/M405F

Pictures

1984 - M405F - 018.jpg1984 - M405F - 019.jpg1984 - M405F - 020.jpg1984 - M405F - 021.jpg1984 - M405F - 022.jpg1984 - M405F - 023.jpg1984 - M405F - 024.jpg1984 - M405F - wbsps - module - m405f - test meter.jpg1984 - M405F - wbsps - module - m405f - test meter_small.jpgM405F - 024(1).jpg19xx - AD - wbsps - ad - made to measure.jpg1975 - M405 - 001 (2).jpg1975 - M405 - 001.jpg

Front panel

Dates found in the documents

Year Kind Text File
1984|17 manual issue date MANUAL ISSUE #1 JUNE 1984 1984 - M405F - 018.jpg

Physical manual inventory

Item Location Status Scanned
M405F, EXTENDED RANGE VU METER LOOSE BOX

Photos & scans (10)

Year File
1984|17 1984 - M405F - 018.jpg note
1984|17 1984 - M405F - 019.jpg note
1984|17 1984 - M405F - 020.jpg note
1984|17 1984 - M405F - 021.jpg note
1984|17 1984 - M405F - 022.jpg note
1984|17 1984 - M405F - 023.jpg note
1984|17 1984 - M405F - 024.jpg note
1984|17 1984 - M405F - wbsps - module - m405f - test meter.jpg note
1984|17 1984 - M405F - wbsps - module - m405f - test meter_small.jpg note
? M405F - 024(1).jpg note

Named in other drawings & documents (4)

File Page
19xx - AD - wbsps - ad - made to measure.jpg 1
19xx - M405 - AD - wbsps - ad - made to measure.jpg 1
1975 - M405 - 001 (2).jpg 1
1975 - M405 - 001.jpg 1

From the manuals

Each manual split into its sections. Text that is the same in many Ward-Beck manuals (warranty, address, standard notes) is kept once on the Boilerplate page and linked.

Specifications (2)

Technical Data — 188 words · 1984 - M405F - 020.jpg, page 1

MLosF EXTENDED RANGE vu METER Range: 50 dBm to +30 dBm in reading dB steps for vu Input Selection: Pushbutton selects between two sources ADC PJ339 type jack on front panel provides direct input. Source mpedance 600 ohms or 150 ohms _ Input mpedance 600 ohms, 150 ohms or 20k ohms floating Attenuator Tracking: +/ - 0.25 dB per step (non accumulative) Meter Ballistics: Complies with ANSI C16.5 High Pass Filter: -3 dB at 250 Hz .

-24 dB at 120 Hz _ Frequency Response Metering +/ - 0 . 25 dB from 30 Hz to 15 kHz . Monitoring Outputs: +/- 0.5 dB from 50 Hz to 10 kHz . Total Harmonic Distortion: Headset Output: Less than 1% , 50 Hz to 10 kHz (measured at any input level and at +24 dBm output level ) _ Speaker Output: Less than 1% , 50 Hz to 10 kHz (measured at any input level and at watts, ohms output level ) Noise: 40 dB below vu reference Output mpedance Headset Output: 150 ohms.

Speaker Output: ohms max mum. Load Impedance Headset Output: 600 ohms, balanced Speaker Output: ohms_

Technical Data — 66 words · 1984 - M405F - 021.jpg, page 1

M4O5F EXTENDED RANGE vu METER Output Levels: Headset Output: +8 dBm nominal into reference) +24 dBm max 600 ohm load for vu Speaker Output: watts into ohms max: Power Requirements 105 to 125 vol t5, 50/60 Hz 30 Va . Ambient Temperature: %c to 608c _ Dimensions: 19" wide (483 mm 10" deep 3-1/2" high. 254 mm 89 mm) Weight: 12 Ib _ (5.5 kg.) 1-2

Drawings (1)

Read from the drawing title blocks.

Drawing Title Date Drawn by Checked by Iss. Source
— file
An archive by Anthony Peter Kuzub · WBSps.Kuzub.com · WBSps.ca
generated from M405F.md