M405F
| Type | module |
| Category | METER |
| Try it | simulator & front panel · download package (zip) |
| Earliest dated evidence | 1984|17 — manual issue date |
| Evidence | "MANUAL ISSUE #1 JUNE 1984" in PUBLIC/Manuals + tech DOCUMENTS/METERING/M405F---Extended-Range-VU-meter-/M405F - 018.jpg |
| Confidence | high |
| All years found | 1984|17 |
| Variants | M405, M405C, M405D, M405M, M405P, M405PSS |
| Folder | Modules/METER/M405F |
Pictures
1984 - M405F - 018.jpg
1984 - M405F - 019.jpg
1984 - M405F - 020.jpg
1984 - M405F - 021.jpg
1984 - M405F - 022.jpg
1984 - M405F - 023.jpg
1984 - M405F - 024.jpg
1984 - M405F - wbsps - module - m405f - test meter.jpg
1984 - M405F - wbsps - module - m405f - test meter_small.jpg
M405F - 024(1).jpg
19xx - AD - wbsps - ad - made to measure.jpg
1975 - M405 - 001 (2).jpg
1975 - M405 - 001.jpgFront panel
Dates found in the documents
| Year | Kind | Text | File |
|---|---|---|---|
| 1984|17 | manual issue date | MANUAL ISSUE #1 JUNE 1984 |
1984 - M405F - 018.jpg |
Physical manual inventory
| Item | Location | Status | Scanned |
|---|---|---|---|
| M405F, EXTENDED RANGE VU METER | LOOSE BOX |
Photos & scans (10)
| Year | File | |
|---|---|---|
| 1984|17 | 1984 - M405F - 018.jpg | note |
| 1984|17 | 1984 - M405F - 019.jpg | note |
| 1984|17 | 1984 - M405F - 020.jpg | note |
| 1984|17 | 1984 - M405F - 021.jpg | note |
| 1984|17 | 1984 - M405F - 022.jpg | note |
| 1984|17 | 1984 - M405F - 023.jpg | note |
| 1984|17 | 1984 - M405F - 024.jpg | note |
| 1984|17 | 1984 - M405F - wbsps - module - m405f - test meter.jpg | note |
| 1984|17 | 1984 - M405F - wbsps - module - m405f - test meter_small.jpg | note |
| ? | M405F - 024(1).jpg | note |
Named in other drawings & documents (4)
| File | Page |
|---|---|
| 19xx - AD - wbsps - ad - made to measure.jpg | 1 |
| 19xx - M405 - AD - wbsps - ad - made to measure.jpg | 1 |
| 1975 - M405 - 001 (2).jpg | 1 |
| 1975 - M405 - 001.jpg | 1 |
From the manuals
Each manual split into its sections. Text that is the same in many Ward-Beck manuals (warranty, address, standard notes) is kept once on the Boilerplate page and linked.
Specifications (2)
Technical Data — 188 words · 1984 - M405F - 020.jpg, page 1
MLosF EXTENDED RANGE vu METER Range: 50 dBm to +30 dBm in reading dB steps for vu Input Selection: Pushbutton selects between two sources ADC PJ339 type jack on front panel provides direct input. Source mpedance 600 ohms or 150 ohms _ Input mpedance 600 ohms, 150 ohms or 20k ohms floating Attenuator Tracking: +/ - 0.25 dB per step (non accumulative) Meter Ballistics: Complies with ANSI C16.5 High Pass Filter: -3 dB at 250 Hz .
-24 dB at 120 Hz _ Frequency Response Metering +/ - 0 . 25 dB from 30 Hz to 15 kHz . Monitoring Outputs: +/- 0.5 dB from 50 Hz to 10 kHz . Total Harmonic Distortion: Headset Output: Less than 1% , 50 Hz to 10 kHz (measured at any input level and at +24 dBm output level ) _ Speaker Output: Less than 1% , 50 Hz to 10 kHz (measured at any input level and at watts, ohms output level ) Noise: 40 dB below vu reference Output mpedance Headset Output: 150 ohms.
Speaker Output: ohms max mum. Load Impedance Headset Output: 600 ohms, balanced Speaker Output: ohms_
- source: 1984 - M405F - 020.jpg, p. 1
Technical Data — 66 words · 1984 - M405F - 021.jpg, page 1
M4O5F EXTENDED RANGE vu METER Output Levels: Headset Output: +8 dBm nominal into reference) +24 dBm max 600 ohm load for vu Speaker Output: watts into ohms max: Power Requirements 105 to 125 vol t5, 50/60 Hz 30 Va . Ambient Temperature: %c to 608c _ Dimensions: 19" wide (483 mm 10" deep 3-1/2" high. 254 mm 89 mm) Weight: 12 Ib _ (5.5 kg.) 1-2
- source: 1984 - M405F - 021.jpg, p. 1
Drawings (1)
Read from the drawing title blocks.
| Drawing | Title | Date | Drawn by | Checked by | Iss. | Source |
|---|---|---|---|---|---|---|
| — | file |