IndexWiki homeTimelineSearchStatus

M901CY

Type module
Category UNSORTED
Try it simulator & front panel · download package (zip)
Earliest dated evidence 1994|27 — used in a dated job
Evidence job 940444
Confidence low (in use by)
All years found 1994|27, 1995|28, 1996|29
Used in jobs 940444 (1994|27)
Variants M901, M901A, M901B, M901BY, M901C, M901D, M901NW
Folder Consoles/1990-1999/940444 - WBZ
Folder DOCUMENTS/RECENT SCANS/WBSps.ca 20210317 - Large pile of D
Folder DOCUMENTS/RECENT SCANS/WBSps.ca 20210319 - Redone of what Sampson scanned

Connections

What it is made of and what it is part of.

Pinout & connections

No page of its own numbers M901CY's contacts: these are its variant M901D's, drawn faded — not confirmed for M901CY.

EDGE CONNECTOR · 1–46NUMBERED SIDE · AS ON M901D1234567891011121314151617181920212223242526272829303132333435: MOMENTARY CLOSURE TO CONTROL COMMON VIA AN ground / common · confidence variant (from a variant) prose · 1995 - M901D - 901-01-006 - COMPONENT LAYOUT.wp, p. 1 “A momentary closure to control common via an open collector transistor which follows source selection is available at module connector P2 pin 36 and P2 pin 35 …”35MOMENTARY CLOSURE TO C…GND36: MOMENTARY CLOSURE TO CONTROL COMMON VIA AN ground / common · confidence variant (from a variant) prose · 1995 - M901D - 901-01-006 - COMPONENT LAYOUT.wp, p. 1 “A momentary closure to control common via an open collector transistor which follows source selection is available at module connector P2 pin 36 and P2 pin 35 …”36MOMENTARY CLOSURE TO C…GND3738394041: CUE CHANNEL TOGGLES ON AND OFF audio bus / pair · confidence variant (from a variant) prose · 1995 - M901D - 901-01-006 - COMPONENT LAYOUT.wp, p. 1 “This alternate action can be invoked by either momentarily closing Cue switch SW1 (Q), or momentarily grounding the external Cue control input at module connec…”41CUE CHANNEL TOGGLES ON…BUS42434445: LAMP INTEGRAL TO THE CHANNEL OFF SWITCH control / tally · confidence variant (from a variant) prose · 1995 - M901D - 901-01-006 - COMPONENT LAYOUT.wp, p. 1 “The lamp integral to the Channel Off switch is uncommitted and available at module connector P2 pins 45 and 46.”45LAMP INTEGRAL TO THE C…CTL46: LAMP INTEGRAL TO THE CHANNEL OFF SWITCH control / tally · confidence variant (from a variant) prose · 1995 - M901D - 901-01-006 - COMPONENT LAYOUT.wp, p. 1 “The lamp integral to the Channel Off switch is uncommitted and available at module connector P2 pins 45 and 46.”46LAMP INTEGRAL TO THE C…CTL
KEYBUS audio bus / pairGND ground / commonCTL control / tallyvariant
M901CYpins as on its variant M901D (not confirmed for M901CY)M901CYCUE CHANNEL TOGG…41MOMENTARY CLO… 35·36LAMP INTEGRAL… 45·46CONNECTED TO · CONSOLES & JOBS (1)940444WBZ BOSTON - CONTROL ROOM R…DRAWN WITH · MODULES (5)M907on 6 drawings with itM908on 6 drawings with itM901BYon 4 drawings with itM901Con 3 drawings with itM901Bon 1 drawing with it

pinout (SVG) · connections (SVG) · pins (JSON)

Pin evidence — 5 contacts
PinSignalKindConfidenceRead fromSource
35MOMENTARY CLOSURE TO CONTROL COMMON VIA ANground / commonvariantprose1995 - M901D - 901-01-006 - COMPONENT LAYOUT.…, p. 1
“A momentary closure to control common via an open collector transistor which follows source selection is available at module connector P2 p…”
36MOMENTARY CLOSURE TO CONTROL COMMON VIA ANground / commonvariantprose1995 - M901D - 901-01-006 - COMPONENT LAYOUT.…, p. 1
“A momentary closure to control common via an open collector transistor which follows source selection is available at module connector P2 p…”
41CUE CHANNEL TOGGLES ON AND OFFaudio bus / pairvariantprose1995 - M901D - 901-01-006 - COMPONENT LAYOUT.…, p. 1
“This alternate action can be invoked by either momentarily closing Cue switch SW1 (Q), or momentarily grounding the external Cue control in…”
45LAMP INTEGRAL TO THE CHANNEL OFF SWITCHcontrol / tallyvariantprose1995 - M901D - 901-01-006 - COMPONENT LAYOUT.…, p. 1
“The lamp integral to the Channel Off switch is uncommitted and available at module connector P2 pins 45 and 46.”
46LAMP INTEGRAL TO THE CHANNEL OFF SWITCHcontrol / tallyvariantprose1995 - M901D - 901-01-006 - COMPONENT LAYOUT.…, p. 1
“The lamp integral to the Channel Off switch is uncommitted and available at module connector P2 pins 45 and 46.”

Pictures

1994 - 940444 - DOC - 940444-03-006 - LOVG FULL RAD SLOT SEE NOTE DOR ENTATIONS.jpg1994 - 940444 - DOC - 940444-04-001 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg1994 - M901CY - CONNECTOR LAYOUT.jpg1994 - 940444-03-006 - M901BY CY CUSTOM INPUT MODULES - DRN DRG - ISS 1.jpg1994 - 940447 - DOC - 940447-04-002 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg1994 - 940448 - DOC - 940448-04-002 - ODULES ARE WIRED BUT NOT SUPPLIIED INITIALLY FUTURE.jpg1996 - 960243 - DOC - 2021-3-17-0-1-35.jpg

Photos & scans (10)

Year File
1994|27 1994 - 940444 - DOC - 940444-03-006 - LOVG FULL RAD SLOT SEE NOTE DOR ENTATIONS.jpg note
1994|27 1994 - 940444 - DOC - 940444-04-001 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg note
1994|27 1994 - DOC - 940444-03-006 - LOVG FULL RAD SLOT SEE NOTE DOR ENTATIONS.jpg note
1994|27 1994 - DOC - 940444-04-001 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg note
1994|27 1994 - M901BY - DOC - 940444-03-006 - LOVG FULL RAD SLOT SEE NOTE DOR ENTATIONS.jpg note
1994|27 1994 - M901CY - CONNECTOR LAYOUT.jpg note
1994|27 1994 - M901CY - DOC - 940444-03-006 - LOVG FULL RAD SLOT SEE NOTE DOR ENTATIONS.jpg note
1994|27 1994 - M901CY - DOC - 940444-04-001 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg note
1994|27 1994 - M907 - DOC - 940444-04-001 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg note
1994|27 1994 - M908 - DOC - 940444-04-001 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg note

Consoles & jobs it is connected to (1)

Their own drawings name this module.

Job Year Drawing Page
940444 1994|27 1994 - 940444-03-006 - M901BY CY CUSTOM INPUT MODULES - DRN DRG - ISS 1.jpg 1

Named in other drawings & documents (19)

File Page
1994 - 940447 - DOC - 940447-04-002 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg 1
1994 - 940448 - DOC - 940448-04-002 - ODULES ARE WIRED BUT NOT SUPPLIIED INITIALLY FUTURE.jpg 1
1994 - DOC - 940447-04-002 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg 1
1994 - DOC - 940448-04-002 - ODULES ARE WIRED BUT NOT SUPPLIIED INITIALLY FUTURE.jpg 1
1994 - M901 - DOC - 940448-04-002 - ODULES ARE WIRED BUT NOT SUPPLIIED INITIALLY FUTURE.jpg 1
1994 - M907 - DOC - 940447-04-002 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg 1
1994 - M907 - DOC - 940448-04-002 - ODULES ARE WIRED BUT NOT SUPPLIIED INITIALLY FUTURE.jpg 1
1994 - M908 - DOC - 940447-04-002 - OTHERS ELECTRICALLY AND MECHANICALLY INTEGRATED INTO CONSOLE.jpg 1
1994 - M908 - DOC - 940448-04-002 - ODULES ARE WIRED BUT NOT SUPPLIIED INITIALLY FUTURE.jpg 1
1995 - M405P - ITEMIMP(1).TXT (2).docx 1
1995 - M405P - ITEMIMP(1).TXT.docx 1
1995 - M405P - ITEMIMP.TXT.docx 1
1996 - 960243 - DOC - 2021-3-17-0-1-35.jpg 1
1996 - DOC - 2021-3-17-0-1-35.jpg 1
1996 - M901BY - DOC - 2021-3-17-0-1-35.jpg 1
1996 - M905A - DOC - 2021-3-17-0-1-35.jpg 1
1996 - M907 - DOC - 2021-3-17-0-1-35.jpg 1
1996 - M908 - DOC - 2021-3-17-0-1-35.jpg 1
1996 - M909 - DOC - 2021-3-17-0-1-35.jpg 1

Drawings (2)

Each scan with its trace laid over it: the slider runs from the scan to the vector drawing. Click one to see it large and save it as SVG, DXF, KiCad, PDF or PowerPoint.

940444-04-001 · connector layout · 1994|27
Others Electrically And Mechanically Integrated Into Consoleviewer
940444-03-006 · mechanical · 1994|27
Lovg Full Rad Slot See Note Dor Entationsviewer

Read from the drawing title blocks.

Drawing Title Date Drawn by Checked by Iss. Source
940444-03-006 Lovg Full Rad Slot See Note Dor Entations DRG file
940444-04-001 Others Electrically And Mechanically Integrated Into Console SM C file
An archive by Anthony Peter Kuzub · WBSps.Kuzub.com · WBSps.ca
generated from M901CY.md