POD3 — Stereo Level VU Meter
| Type | product |
| Series | PODS |
| Try it | simulator & front panel · download package (zip) |
| Earliest dated evidence | 1994|27 — month & year |
| Evidence | "Sep-94" in WBSps Engineering from H drive-20261018T013433Z-1-001/WBSps Engineering from H drive/WBSps - POD_OLD/POD3/#ESP_OUT.TXT |
| Confidence | medium |
| All years found | 1994|27, 1995|28, 1996|29, 1997|30 |
| Variants | POD3A |
| Folder | Products/PODS/POD3 |
Pictures
Front panel
Dates found in the documents
Documents (6)
Drawings & design files (23)
From the manuals
Each manual split into its sections. Text that is the same in many Ward-Beck manuals (warranty, address, standard notes) is kept once on the Boilerplate page and linked.
Specifications (1)
Specifications — 104 words · 1997 - POD3 - POD3 - MAXIMUM INPUT LEVEL - SPECIFICATIONS.wpd, page 1
Frequency Response: ±1.0 dB, 20 Hz to 20 kHz Maximum Input Level: at 0 dBu: +21 dBu at + 4 dBu: +25 dBu at +8 dBu: +29 dBu Stereo Separation: Greater then the meters resolution Sensitivity Range: 0 dBu to +8 dBu for a 0 VU reading Input Impedance: 30,000 Ω or greater, balanced Source Impedance: 600 Ω or less, balanced Common Mode Rejection: Greater than 70 dB at 60 Hz Meter Ballistics: Comply with ANSI C165 Power Requirements: 110 or 220 Volts ac, 60 or 50 Hz, 12 VA Ambient Temperature 0°to 50° Celsius Dimensions 8.69" wide x 1.73" high x 7.0" deep
Operation (1)
Operation — 154 words · 1996 - POD3 - POD3 - STEREO PEAK-VU LEVEL INDICATOR - WIRING.wp, page 1
FROM 110 VOLTS ac:
■ Two jumpers must be present, one connection Y1 to Y2, the other connection Y3 and Y4. This corresponds to JP2 and JP3 being in place.
FOR
FROM 220 VOLTS ac:
■ One jumper must be present, connecting Y2 and Y3. This corresponds to JP1 being in place.
Frequency Response: ±1.0 dB, 20 Hz to 20 kHz. Maximum Input Level: +21 dBu, balanced. Stereo Separation: Greater than the meter's resolution
Range: 0 dBu to +8 dBu for a 0 VU reading.
Input Impedance: 30 000 ohms or greater, balanced.
Source Impedance: 600 ohms or less, balanced.
Common Mode Rejection: Greater than 70 dB at 60 Hz. Power Requirement: 110 or 220 volts ac, 60 or 50 Hz; 5 Watts.
Ambient Temperature: 0o to 50o Celsius.
Relative Humidity: 20 % to 90 %, non-condensing.
Dimensions: 8.69" wide x 1.73" high x 7.00" deep (221 mm x 44 mm x 178 mm)