M405M — Extended Range VU Monitoring System

Type module
Category METER
Try it simulator & front panel · download package (zip)
Earliest dated evidence 1995|28 — manual issue date
Evidence "Issue #1 March 20, 1995" in WBSps Engineering from H drive-20261018T013433Z-1-001/WBSps Engineering from H drive/WBSps - Word Perfect Manuals/M405M.WP
Confidence high
All years found 1995|28
Variants M405, M405C, M405D, M405F, M405P, M405PSS
Folder Modules/METER/M405M

Connections

What it is made of and what it is part of.

Pictures

1995 - M405M - Archived - M405M - METER - MONITOR 001.jpg1995 - M405M - Archived - M405M - METER - MONITOR 002.jpg1995 - M405M - Archived - M405M - METER - MONITOR 003.jpg1995 - 405-03-082 - M405M PCB CONNECTOR BRACKET - DRN DRG - ISS 1.jpg

Dates found in the documents

Year Kind Text File
1995|28 manual issue date Issue #1 March 20, 1995 1995 - M405M - 14-292-02-003 - 3 P1 CONNECTOR 3-1 - LAYOUT.wp

Documents (1)

Year File
1995|28 1995 - M405M - 14-292-02-003 - 3 P1 CONNECTOR 3-1 - LAYOUT.wp note

Photos & scans (3)

Year File
1995|28 1995 - M405M - Archived - M405M - METER - MONITOR 001.jpg note
1995|28 1995 - M405M - Archived - M405M - METER - MONITOR 002.jpg note
1995|28 1995 - M405M - Archived - M405M - METER - MONITOR 003.jpg note

Sub-assemblies & parts used (1)

Item What Family Year How we know
SA14-292 3 P1 CONNECTOR 3-1 - LAYOUT Circuit boards (SA14-nnn) its circuit board

Parts list — board 14-292 (17 parts)

From 14-292#2.WP; also in timelines/data/bom.csv.

Ref Part Value Manufacturer Mfr part no.
C1 Capacitor 10 uF/25 V ITT 10M25
C10 delete
C11 Capacitor 1 uF/35 V ITT 1M35
CR1 Diode Motorola 1N4148
P3 Connector, 2 Pin Bergstik Berg 65645-202
Q1 Transistor National 2N3906
R1 Resistor 1/4W 5% 47K Philips CR25
R11 Resistor 1/4W 1% 9K09 Philips MRS 25F
R16 Resistor 1/4W 5% 43K Philips CR25
R17 Potentiometer 50K Piher PT10V 50K
R18 Resistor 1/4W 5% 22K Philips CR25
R29 Resistor 1/4W 5% 4K7 Philips CR25
R33 delete
R34 Potentiometer 20K Piher PT10V 20K
R35 Resistor 1/4W 5% 47K Philips CR25
U1 Integrated Circuit National LM833N
U1, U3 8 Pin Dip Socket AMP 640463-3

Parts list — board M405M (8 parts)

From M405M.WP; also in timelines/data/bom.csv.

Ref Part Value Manufacturer Mfr part no.
A1 VU Meter Amplifier WBS SA14-292B
A2 Intercom pre and Output Amplifier WBS M703C
F1 314 Amp fast blow fuse Buss AGC0.75
J1 Jack 1/4" headphone Switchcraft NL-11413
LS1 Speaker Misco DC22S
M1 Vu Meter Bach-Simpson 544WL
R1 Speaker Level Clarostat WBS 10-073
SW1-SW7 Switch Schadow 2CF-GHT-AA

Named in other drawings & documents (4)

File Page
1995 - 405-03-082 - M405M PCB CONNECTOR BRACKET - DRN DRG - ISS 1.jpg 1
1995 - M405P - ITEMIMP(1).TXT (2).docx 1
1995 - M405P - ITEMIMP(1).TXT.docx 1
1995 - M405P - ITEMIMP.TXT.docx 1

From the manuals

Each manual split into its sections. Text that is the same in many Ward-Beck manuals (warranty, address, standard notes) is kept once on the Boilerplate page and linked.

Specifications (1)

Technical Data — 301 words · 1995 - M405M - 14-292-02-003 - 3 P1 CONNECTOR 3-1 - LAYOUT.wp, page 1

M405M EXTENDED RANGE VU MONITORING SYSTEM

Range: -10 dBu to +10 dBu in five steps.

Input Selection: Pushbutton select between two sources.

Source Impedance: 600 ohms or less, balanced.

Input Impedance: Greater than 20K ohms.

Attenuator Tracking: ±0.25dB per step, non-cumulative.

Meter Ballistics: Complies with ANSI C16.5.

Frequency Response: ±0.25 dB 30 Hz to 15 kHz.

Monitor Output: ±1 dB from 100 Hz to 5 kHz.

Total Harmonic Distortion Headset Output: Less than 1%, from 50 Hz to 10 kHz. Speaker Output: Less than 1%, 50 Hz to 10 kHz

Noise: 40 dB below 0 VU reference. GENERAL

M405M EXTENDED RANGE VU MONITORING SYSTEM

The M405M has been designed to measure and monitor the average level of an audio signal. This instrument is self-contained and mounts in an EIA standard 19" equipment rack. It is powered by a 24 volt DC wall mount power supply.

A "range" attenuator, providing 5 steps (-10, 0, +4, +8, +10 dBu), accommodates audio input levels from -10 to +10 dBu for a 0 meter reading. The M405M accepts two inputs (A or B) at the rear of the instrument. Selection between the A or B inputs may be made by a pushbutton selector on the front of the unit.

An internal speaker, complete with level control, is mounted in the front panel to permit the user to listen to the source being metered. A headset jack is also provided on the front panel for headphone monitoring. A1 VU Meter Amplifier WBS SA14-292B

A2 Intercom pre and Output Amplifier WBS M703C

F1 314 Amp fast blow fuse Buss AGC0.75

J1 Jack 1/4" headphone Switchcraft NL-11413

LS1 Speaker Misco DC22S

M1 Vu Meter Bach-Simpson 544WL

R1 Speaker Level Clarostat WBS 10-073

SW1-SW7 Switch Schadow 2CF-GHT-AA

M405M

EXTENDED RANGE VU MONITORING SYSTEM Issue #1 March 20, 1995 MW94002/M405M.WP